S Scania Multi 📌 unpin — ▢ ×
Pinned chassis: 1158127 R113ML4X2L 36050Z 942650 Unpin
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › BCI2 BCI2 / 0255

Short circuit to battery for PWMO 4

â–¶ How to fix

Check wiring and connectors.

What you'll see

No driver-visible symptom recorded.

System reaction

Output operational status shall be set to disabled. The status of the pin shall be indicated as Not Available/Error. Yellow warning in the instrument cluster.

Diagnostic depth

Detection

Short circuit to battery for PWMO 4

Possible cause

Defect wiring - open circuit - short circuit to supply voltage Defect connectors

{ } Raw XML
diag