S Scania Multi 📌 unpin — ▢ ×
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › BCI2 BCI2 / 0282

PWM1 output is overloaded (current > 3A )

â–¶ How to fix

Check wiring, connectors and load connected to PWM1 output.

What you'll see

No driver-visible symptom recorded.

System reaction

Output operational status shall be set to disabled. The status of the pin shall be indicated as Not Available/Error. Yellow warning in the instrument cluster.

Diagnostic depth

Detection

PWM1 output is overloaded (output current > 3A )

Possible cause

Defect wiring - defect load - defect connectors

{ } Raw XML