S Scania Multi 📌 unpin — ▢ ×
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › DAS2 DAS2 / 032A

All outputs are enabled when they should be disabled.

â–¶ How to fix

Replace the DAS2 ECU.

What you'll see

Outputs may be enabled despite the fact that an unmanageable error has been detected. Power-supply to sensors may be unintentionally activated. This will affect the stay-alive functionality of the system and delay shut-down and increase power consumption when ignition is turned off.

System reaction

Amber DAS Warning Lamp

Diagnostic depth

Detection

Feedback signal OEW_Feedback indicates that the outputs are enabled even though the watchdog OEW_Ack_Toggle is not being toggled. The DTC is set to active if all conditions below have been fulfilled for more than 10 seconds. • The OEW toggling state from ComP == ‘Not toggling’ • OEW_Feedback == 'Enabled' The DTC is set to inactive if all conditions below have been fulfilled for more than 10 seconds. • The OEW toggling state from ComP == ‘Not toggling’ • OEW_Feedback == 'Disabled' The DTC is not set to active in the following cases: • Ignition is turned off. • First 2 seconds after ignition on. • System supply voltage (U30) is below 22 volt. • System supply voltage (U30) is above 32 volt.

Possible cause

Hardware malfunction.

{ } Raw XML
diag