FLC Power Exceeded TO BE REMOVED

â–¶ How to fix

Measure the resistance between DAS2(pin A30) and FLC. Check cable harness between DAS2(pin A30) and FLC. Remove FLC and measure resistance between DAS2 pin A30 and ground. The resistance should be high between DAS2 pin and ground, otherwise there is a short-circuit to ground.The resistance between DAS2 pin A30 and the power supply pin in the FLC connector should however be close to 0 ohms to secure an appropriate supply. Change sensor.

What you'll see

Other DTC could be set as a consequence of sensor not getting power

System reaction

No system-reaction text recorded.

Diagnostic depth

Detection

The DTC is set active if one of the following conditions are met: - The current supplied at Power output 3 (power output for FLC) is too high (>2.5A) for 1s, while the signal status of current sense is good. - The current supplied at Power output 3 (power output for FLC) is too high (>0.8A) for 6s, while the signal status of current sense is good and ALL_ECU_ON is set to true. The DTC is not set in the following cases: - Ignition is turned off. - First 2 seconds after ignition on. - System voltage is below 22V - System voltage is above 32V

Possible cause

Faulty cable connecting Power output 3 (POWER_OUT_3) Short circuit to ground.