S Scania Multi 📌 unpin — ▢ ×
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › EST1 EST1 / 0226

The Electric motor (M53) in the MPU has stopped due to over temperature, blocked or jammed.

â–¶ How to fix

• If DTC is active: Read signal RTDB_MPU_OVER_TEMP_CUTOFF_E (F449) and RTDB_MPU_MOTOR_BLOCKED_CUTOFF_E (F447) to see root cause of fault. • Check MPU unit for mechanical faults, in pump, or el. motor (M53) Verify that the issue is solved by performing a Diagnostic SelfTest (requires Parking Brake to be applied) - If the root cause fault has been fixed, this DTC will be set passive.

What you'll see

No driver-visible symptom recorded.

System reaction

Red Steer tag axle fault warn EST in released or fixed mode

Diagnostic depth

Detection

The electric motor(M53) in the MPU has stopped due to over temperature, beeing blocked or jammed. Component code M53.

Possible cause

• Motor/electronics/environment too hot: - Insufficient cooling - very high ambient temperature and excessive use • MPU pump drive torque exceeds the maximum motor torque during start-up, • Reports mechanical failure if temperature is equal or higher than 100°C considering all load conditions.

{ } Raw XML
diag