S Scania Multi 📌 unpin — ▢ ×
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › EST1 EST1 / 0228

MPU electric motor has stopped due to high supply voltage.

â–¶ How to fix

• Check wiring • Check connectors • Check sensor: - Switch on battery (connections / master switch) and measure voltage on MPU power terminals (M6 screws). It should be approximately 24 volt (battery voltage). - Compare measured value to value read from CID 0xF487 (MPU supply voltage), using SDP3. - If there is a significant divergence/difference (more than 5 volt) the electrical motor (M53) in the MPU has to be replaced. Verify that the issue is solved by performing a Diagnostic SelfTest (requires Parking Brake to be applied) - If the root cause fault has been fixed, this DTC will be set passive.

What you'll see

No driver-visible symptom recorded.

System reaction

Red Steer tag axle fault warn EST in released or fixed mode

Diagnostic depth

Detection

MPU component code M53 has detected high supply voltage.

Possible cause

• Defect wiring - open circuit on sensor ground - short circuit to supply voltage • Defect connectors • Defect sensor