Handwash Fill Valve Error, Short to Ground Short to Battery
â–¶ How to fix
- Check the hand wash fill valve. - Check the wiing to valve for short to supply and ground.
What you'll see
Handwash tank may not fill up or may cause overflow.
System reaction
No system-reaction text recorded.
Diagnostic depth
Detection
The Hand wash tank filling valve has a short circuit to battery or short to ground.
Possible cause
- faulty valve. - valve supply or ground connection.