Emergency switch indicator Error, Short to Battery Short to Ground
â–¶ How to fix
- check the emergency switch indicator teltale. - check the switch and wiring for short circuit
What you'll see
Emergency alarm status is not indicated correctly.
System reaction
No system-reaction text recorded.
Diagnostic depth
Detection
The indicator of emergency switch in toilet cabin has short circuit to gnd or supply
Possible cause
- Faulty the emergency switch indicator teltale. - Faulty wiring to the switch