DTC ›
BCI1
| Code | Heading | Variants |
|---|---|---|
| 0200 | ECU hardware memory failure | 10× |
| 0201 | Illegal software operation | 10× |
| 0202 | Overloaded software resources | 10× |
| 0203 | Inconsistent long term RAM data | 10× |
| 0204 | Loss of KWP2000-ECU ID data | 10× |
| 0205 | Loss of operation data | 10× |
| 0206 | Loss of function parameters | 10× |
| 0207 | Electrical error on Yellow CAN bus (CAN1 BusOff) | 10× |
| 0208 | Absence of Yellow bus CAN communication (CAN1 buffer overflow) | 10× |
| 0209 | TCO node: timeout in CAN communication | 10× |
| 020A | EMS node: timeout in CAN communication | 10× |
| 020B | Inconsistent PIN-Coding for expansion units | 5× |
| 020C | Electrical error on external CAN bus | 10× |
| 020D | Electrical error on tag/middle axle brake air pressure sensor. Voltage is too high. | 10× |
| 020E | Electrical error on tag/middle axle brake air pressure sensor. Voltage is too low. | 10× |
| 020F | Incompatible signals from the 3 way engine start switch placed in the engine room. | 10× |
| 0210 | Parking Brake Sensors are malfunctioning | 10× |
| 0211 | Absence of external bus CAN communication (CAN3 buffer overflow) | 10× |
| 0212 | Absence of expansion CAN bus communication (CAN2 buffer overflow) | 10× |
| 0213 | Electrical error on expansion CAN bus | 10× |
| 0214 | Implausible signal from steered tag axle flow sensor | 10× |
| 0215 | Steered tag axle shift valve not connected | 10× |
| 0216 | Electrical error on FMS CAN bus | — |
| 0217 | Absence of FMS bus CAN communication (CAN4 buffer overflow) | — |
| 0218 | Electrical error on additional fuel level sensor. Voltage is to low. | 10× |
| 0219 | Electrical error on additional fuel level sensor. Sensor is missing/error. | 10× |
| 021A | Unconfigured expansion unit. | 10× |
| 021B | BIC-program contains a signal/pin not available for current vehicle configuration | 10× |
| 021C | Invalid BIC-program | 10× |
| 021D | Expansion unit bus: Network configuration error | 9× |
| 021E | Expansion unit A: Network configuration error | 9× |
| 021F | Expansion unit B: Network configuration error | 9× |
| 0220 | Expansion unit C: Network configuration error | 9× |
| 0221 | Expansion unit D:Network configuration error | 9× |
| 0222 | Expansion unit E:Network configuration error | 9× |
| 0223 | Expansion unit F:Network configuration error | 9× |
| 0224 | Expansion unit G:Network configuration error | 9× |
| 0225 | Expansion unit H:Network configuration error | 9× |
| 0226 | Expansion unit I:Network configuration error | 9× |
| 0227 | System voltage is below 16 V | 10× |
| 0228 | System voltage is above 32 V | 10× |
| 0229 | APS node: timeout in CAN communication | 10× |
| 022A | COO node: timeout in CAN communication | 10× |
| 022B | EBS node: timeout in CAN communication | 10× |
| 022C | GMS node: timeout in CAN communication | 10× |
| 022D | ICL node: timeout in CAN communication | 10× |
| 022E | Electrical error on indoor temperature sensor. Voltage is too low. | 9× |
| 022F | Electrical error on indoor temperature sensor. Sensor is missing/error. | 9× |
| 0230 | The BIC-program is partially disabled due to faulty input. | 9× |
| 0231 | Sidewalk detection sensor, plausibility check. | 9× |
page 1 of 7