DTC CCC1 103 canonical DTCs
Code Heading Variants
0046
0047
0048
0049
004A
004B
004C
004D
004E
004F
0050
0051
0052
0053
0054
0055
0056
0057
9999 This DTC is set if an INTE (Internal Event) code has been registered.
A00A Evaporator temperature sensor (T212), short circuit to battery, open load, or sensor is broken.
A017 Actuator mix air LIN error.
A020 LIN error on all components.
A023 The U30 12V supply to the climate control system (E138) is below 8V.
A024 The U30 12V supply to the climate control system (E138) is above 16V.
A027 There is an internal electrical error with a safety related feature in the climate control system (E138).
A028 There is an internal electrical error with the climate control system (E138) shutdown mechanism.
A029 12V supply to LIN nodes is short circuit to battery or open load.
A02A 12V supply to LIN node is short circuit to ground.
A02B Each knob has a two channel potentiometer. This faultcode indicates that one of the channels has get stuck.
A02C Each knob has a two channel potentiometer. This faultcode indicates that one of the channels has get stuck.
A02D The calibration for the temperature and fan encoders (knobs) is not valid,
A030 Supply error on mix air/temp flap motor.
A036 Over temp reported by the mix air/temp flap motor.
A03C Permanent electrical fault reported by actuator for mix air/temp.
A047 The climate control system (E138) has detected an error with its memory.
A048 The climate control system (E138) has been restarted due to an internal software operation taking too long time. When a software operation takes longer than expected, a correct functionality of the system can no longer be guaranteed.
A04B Evaporator temperature sensor (T212), short circuit to ground.
A04E Mix air actuator has too small or too large total travel angle.
A058 Secondary Wake Up output is short circuit to ground.
A059 Third Wake Up output is short circuit to ground.
A05A The climate control system (E138) has default data in its EOL configuration.
A05B The climate control system (E138) has been shut down before it finished its normal shutdown procedure, by removing its U30 12V supply.
A05D Panel distribution button stuck
A05E Floor distribution button stuck
A05F AC button stuck
A060 Floor fan actuator LIN error
A061 Floor fan actuator internal error
A062 Floor fan actuator blocked motor or short circuit
A063 Floor fan actuator high temperature
A064 Floor fan actuator high voltage