| Code | Heading | Variants |
|---|---|---|
| 0BB903 | Verification of data in data flash failed. | — |
| 0BBA00 | Read access to data flash failed | — |
| 0BBB00 | Write access to data flash failed. | — |
| 0BBC03 | Check of dataFlash version failed. | — |
| 0BBD00 | ECU motor current offset out of range | — |
| 0BBE03 | Error in CRC computation for Message, VehicleData | — |
| 0BBF00 | Detection of Memory violation | — |
| 0BC008 | Signal, EASActivateBlockingFunct out of defined range | — |
| 0BC108 | Signal, EASAngleCtrlAbsGradLimit out of defined range | — |
| 0BC203 | Received vehicle speed not valid | — |
| 0BC404 | CAN Bus communication failure. | — |
| 0BC504 | Error in CRC computation for Message, EASC3 | — |
| 0BC608 | Fault in EASC1 Message reception | — |
| 0BC708 | Signal, EASHydraulicFlowFactor out of defined range | — |
| 0BC808 | Rotor position sensor signal values out of range | — |
| 0BC908 | Plausibilization of rotor position sensor parameters failed | — |
| 0BCA00 | Failure in Motor Actuator (Output Stage) | — |
| 0BCB00 | Deviation between measured PWM and desired PWM too high | — |
| 0BCC00 | Check for hardware internal voltage plausibalization | — |
| 0BCD00 | Check for hardware ADC working status failed | — |
| 0BCE00 | Start-up check on hardware ASIC failed | — |
| 0BCF00 | Check for motor phase current range | — |
| 0BD000 | General software failures check | — |
| 0BD100 | Check for communication to motor actuator | — |
| 0BD200 | Unexpected Reset by Hardware | — |
| 0BD300 | Check for hardware self-test procedure status | — |
| 0BD400 | Validation check of Hardware Configuration Registers | — |
| 0BD500 | Start-up check for ECU motor control hardware | — |
| 0BD600 | Monitoring of inconsistencies from error sources and monitoring circuits | — |
| 0BD700 | Check for occurrence of floating point exceptions | — |
| 0BD800 | Comparison of calculated and demanded motor torque failed | — |
| 0BD900 | Reduction of assistance torque due to high motor temperature | — |
| 0BDA00 | Check for Hardware Error Event reaction failed | — |
| 0BDB00 | OS Monitoring detected errors | — |
| 0BDC08 | Signal, FrontAxleSpeed out of defined range | — |
| 0BDD03 | Error in the voltage plausibility of TAS sensor torque signals | — |
| 0BDE03 | TAS sensor torque signal values not valid. | — |
| 0BDF03 | Invalid steering angle values from TAS sensor. | — |
| 0BE008 | Signal, ExternalControlModeRequest out of defined range | — |
| 0BE100 | Improper shut-down of ECU. | — |
| 0BE208 | Signal, VehicleGroundSpeed out of defined range | — |
| 0BE400 | Temperature sensor signal values out of range | — |
| 0BE504 | Fault in EASC2 Message reception | — |
| 0BE608 | Steering center position not calibrated | — |
| 0BE803 | Steering angle plausibilization error | — |
| 0BE908 | Signal, EASTorqueReq out of defined range | — |
| 0BEA00 | Diagnosis of Electrical motor hardware | — |
| 0BEB00 | Timing supervision of Electrical motor hardware | — |
| 0BEC08 | Signal, EASSteerWheelVibrPattern out of defined range | — |
| 0BEE00 | Unexpected error triggered from Software/Hardware | — |